2026 Agribusiness Catalog

SPACE HEATING EQUIPMENT

FURNACES Requirements: • Eligibility for furnace and single package vertical unit measures is based on customer having both an eligible electric and natural gas or propane provider. • Furnaces and single package vertical unit must meet the minimum efficiency requirements listed and be a sealed combustion unit. Efficiency ratings will be verified using the AHRI database ( ahridirectory.org ). • Furnaces and single package vertical units must have a single speed, multi-speed, or variable speed electronically communicated motor (ECM). Permanent split capacitor (PSC) motors are not eligible. Air handlers with an ECM are not eligible. • Provide a manufacturer’s specification sheet to document the required features. • Provide input capacity of furnace or single package vertical units (in MBh) in Section 7 on the Rebate Application. • Furnaces must have a multi-stage burner and have at least two firing stages. • Furnaces listed on the Focus on Energy residential furnace qualified products list does not guarantee the furnace has all features required for agribusiness rebates. Application Measure Description Code Rebate Unit

Furnace with ECM, ≥95% AFUE, 2 stages of heat (Natural Gas or Propane) Furnace with ECM, ≥90% AFUE, 2 stages of heat (Natural Gas or Propane)

H3491 H3492

$420 Furnace $200 Furnace

Retrofit

N-H3491

$320

Furnace

New Construction Furnace with ECM, ≥95% AFUE, 2 stages of heat (Natural Gas or Propane)

Furnace with ECM, ≥90% AFUE, 2 stages of heat (Natural Gas or Propane)

N-H3492 $150 Furnace

Reference this table when filling out SECTION 7 on the Rebate Application. EXAMPLE

MANUFACTURER NAME

# OF UNITS (A)

REBATE PER UNIT (B)

TOTAL REBATE (A X B)

CODE

MODEL # UNIT MEASURE

H3491 --------

ABC Furnace

XYZ456

Furnace

1

$420 --------

$420 --------

--------

MBh

80

DIRECT-FIRED MAKE-UP AIR UNIT (MAU) Requirements: • Rebate is available for upgrading from (or installing instead of) indirect-fired make-up air units or rooftop units which are approximately 80% efficient. • Replacement of electric or hydronically heated make-up air is not eligible. • Replacement of a direct-fired unit with a new direct-fired unit is only eligible if the new unit is a variable air volume unit (VAV) replacing a constant air volume (CAV) unit. • Replacement of a VAV make-up air unit is not eligible.

• Direct-fired MAU must serve an occupied space for at least 500 hours per year. • VAV make-up air units (H10030 and H10445) are not eligible for VFD rebates. Application Measure Description

Code Rebate Unit

Direct-Fired MAU, CAV (Natural Gas or Propane) Direct-Fired MAU, VAV (Natural Gas or Propane)

H5081* H10030* H10445* N-H5081* N-H10030* N-H10445*

$0.40 CFM $0.65 CFM $0.25 CFM $0.30 CFM $0.40 CFM $0.20 CFM

Retrofit

Direct-Fired MAU, VAV Replacing Direct-Fired CAV Unit (Natural Gas or Propane)

Direct-Fired MAU, CAV (Natural Gas or Propane) Direct-Fired MAU, VAV (Natural Gas or Propane)

New Construction

Direct-Fired MAU, VAV Replacing Direct-Fired CAV Unit (Natural Gas or Propane)

*Complete Table F1 for Code 5081 and Table F2 for Code 10030 and 10445 on the Supplemental Data Sheet.

30

Powered by