COMPRESSED AIR
VSD AIR COMPRESSORS Requirements: • Submit manufacturer specification sheets and/or a CAGI sheet at anticipated operating pressure for items installed. • Must be variable speed rotary vane compressor or variable speed screw compressor to be eligible. • This is for new VSD compressors only; adding a VSD to an existing compressor does not qualify. • Replacing an old VSD compressor with a new (same size) VSD compressor does not qualify. However, replacement of an old VSD compressor with a new, larger VSD compressor is eligible for the increase in horsepower over the old compressor. For example, if a 50 hp VSD compressor is replaced with a 75 hp VSD compressor, the 25 hp increase in capacity would be eligible for rebates. • Limited to one VSD compressor per compressed air system. • Replaced equipment must be removed. If an old compressor replaced by a VSD compressor remains connected as emergency backup, by signing the application, the customer is attesting that the old compressor will be used only in case of emergency and will rarely (if ever) operate. Application Measure Description Code Rebate Unit Retrofit VSD Compressor replacing Non-VSD Compressor PS2196* $75 hp New Construction VSD Compressor instead of Non-VSD Compressor N-PS2196* $75 hp *Complete Tables E1 and E2 on the Supplemental Data Sheet. NO AIR-LOSS CONDENSATE DRAINS Requirements: • Must be used in systems with load/no-load, variable speed, variable displacement, or centrifugal compressors. • Load/no-load system must have adequate storage for drains to be eligible. • Manual drains, lever-operated mechanical drains, or solenoid drains are not eligible for rebates. • The replacement drain must be “no air-loss,” meaning it must continuously measure the presence of condensate, purge it only when necessary, and only long enough to prevent the unintentional purging of compressed air. • If no air-loss condensate drain is integral to another piece of equipment (i.e., is part of the air compressor, air dryer, mist eliminator, etc.), provide a manufacturer’s specification sheet to confirm. Application Measure Description Code Rebate Unit Retrofit No Air-Loss Condensate Drain PS2254 $130 Drain New Construction No Air-Loss Condensate Drain N-PS2254 $130 Drain For additional compressed air rebate opportunities not shown below, see the Focus on Energy Process Systems Rebate Catalog at focusonenergy.com/catalogs. COMPRESSED AIR AND VACUUM SYSTEM HEAT RECOVERY Requirements: • This rebate is for the installation of a new heat recovery system where one did not exist previously. • Heat recovery system must include automatic controls to switch from winter to summer operation. Systems with only manual damper controls are not eligible. • Replacing an existing heat recovery system or upgrading an existing heat recovery system from manual to automatic controls does not qualify. • The project must result in an estimated net reduction of BTUs consumed in the facility to be eligible. • Rebate is limited to 50% of the project cost, including equipment and external labor . Application Measure Description Code Rebate Unit
PLEASE NOTE
Compressed Air Heat Recovery Vacuum Pump Heat Recovery Compressed Air Heat Recovery Vacuum Pump Heat Recovery
PS2257 PS3928
$75 $75 $75 $75
hp hp hp hp
Retrofit
N-PS2257 N-PS3928
New Construction
26
Powered by FlippingBook