FANS
HIGH-VOLUME LOW-SPEED FAN Requirements: • Enter diameter (in feet) in Units column on the Rebate Application. • If installing multiple fans, enter number of fans and fan diameter (in feet). For example, 5 fans x 16 feet each. • Minimum 16 feet fan diameter. • Submit fan specification sheet with application. Application Measure Description Code Rebate
Unit
Retrofit
High-Volume Low-Speed (HVLS) Fan
AG3998
$100
Fan Diameter (feet)
New Construction
High-Volume Low-Speed (HVLS) Fan
N-AG3998
$100
Fan Diameter (feet)
VENTILATION/EXHAUST FAN — DAIRY APPLICATION Requirements: • Variable speed must be automatically controlled by temperature. • Variable speed fans are not eligible for other variable frequency drive rebates. • Full fan model number and fan diameter must be included on invoice. Application Measure Description
Code
Rebate
Unit
Retrofit
Ventilation/Exhaust Fan, Dairy, ≥ 48” with Variable Speed
AG5089
$425
Fan
New Construction
Ventilation/Exhaust Fan, Dairy, ≥ 48” with Variable Speed
N-AG5089
$425
Fan
VENTILATION/EXHAUST FAN — OTHER APPLICATION (NON-DAIRY) Requirements:
• Must operate a minimum of 4,000 hours annually to be eligible. • Variable speed must be automatically controlled by temperature.
• Variable speed fans are not eligible for other variable frequency drive rebates. • Full fan model number and fan diameter must be included on invoice. Application Measure Description
Code Rebate Unit
Retrofit
Ventilation/Exhaust Fan, Other (non-dairy), ≥ 48” with Variable Speed
AG5095 $325 N-AG5095 $325
Fan Fan
New Construction Ventilation/Exhaust Fan, Other (non-dairy), ≥ 48” with Variable Speed
CIRCULATION FAN — DAIRY APPLICATION Requirements: • Product must meet the performance requirements below. • 36 to 47 inch fans must be greater than or equal to 20.0 lbf/kW. • ≥ 48 inch fans must be greater than or equal to 24.5 lbf/kW.
• Test report must be included with Fan Application to verify performance. Acceptable test report sources include Bio- Environmental and Structural Systems (BESS) labs, an accredited Air Movement and Control Association (AMCA) testing facility, or other third-party lab in accordance with AMCA/ANSI 210 or 230 test procedures. • Full fan model number and fan diameter must be included on invoice. Application Measure Description Code Rebate Unit
Circulation Fan, Dairy, 36-47” (20.0 lbf/kW) Circulation Fan, Dairy, ≥ 48” (24.5 lbf/kW) Circulation Fan, Dairy, 36-47” (20.0 lbf/kW) Circulation Fan, Dairy, ≥ 48” (24.5 lbf/kW)
AG5086 AG5087
$70 $90 $70 $90
Fan Fan Fan Fan
Retrofit
N-AG5086 N-AG5087
New Construction
23
Powered by FlippingBook