FORCED AIR HEAT
UNIT HEATERS Requirements: • Natural gas fired equipment only. Steam or hot water coil/systems are not eligible. • Direct fired rooftop units/make-up air units are not eligible for this rebate.
• Must replace an existing non-condensing unit heater or be installed instead of a non-condensing unit heater. • Provide a manufacturer’s specification sheet to document the features and efficiency level of the unit heater including input capacity in MBh. Measure Description Code Rebate Unit Unit Heater, ≥90% Thermal Efficiency H5436 $4.00 MBh Unit Heater, ≥90% Thermal Efficiency N-H5436 $2.75 MBh
PACKAGED TERMINAL HEAT PUMPS (PTHP) Requirements:
• Unit must be AHRI listed as a Commercial PTHP. AHRI rated efficiency will be used to determine eligibility. • Must replace or be instead of a Packaged Terminal Air Conditioner (PTAC). Replacement of existing PTHP does NOT qualify.
• Window and through-the-wall air conditioners/heat pumps do not qualify. • The equipment size category (BTUh) is the cooling capacity value of the unit. Measure Description
Code H2699 H2702 H2701 H2700
Rebate
Unit PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP
PTHP <8,000 BTUh, ≥10.7 EER, and ≥3.1 COP PTHP 8,000-9,999 BTUh, ≥10.4 EER, and ≥3.0 COP PTHP 10,000-12,999 BTUh, ≥9.9 EER, and ≥2.9 COP PTHP ≥13,000 BTUh, ≥9.3 EER, and ≥2.9 COP PTHP <8,000 BTUh, ≥12.7 EER, and ≥3.1 COP PTHP 8,000-9,999 BTUh, ≥12.1 EER, and ≥3.0 COP PTHP 10,000-12,999 BTUh, ≥10.9 EER, and ≥2.9 COP PTHP ≥13,000 BTUh, ≥10.3 EER, and ≥2.9 COP
$120 $120 $120 $120 $110 $110 $110 $110
N-H2699 N-H2702 N-H2701 N-H2700
DIRECT-FIRED MAKE-UP AIR UNITS (MAU) Requirements: • Rebate is available for upgrading from (or installing instead of) indirect fired make-up air units or rooftop units which are approximately 80% efficient. • Replacement of electric or hydronically heated make-up air is not eligible. • Replacement of a direct fired unit with a new direct fired unit is only eligible if the new unit is a variable air volume (VAV) unit replacing a constant air volume (CAV) unit. • Replacement of a variable air volume (VAV) make-up air unit is not eligible.
• Direct fired make-up air unit must serve an occupied space for at least 500 hours per year. • Variable air volume (VAV) make-up units (H10030 and H10445) are not eligible for VFD rebates. Measure Description Code Rebate
Unit CFM CFM CFM CFM CFM CFM
Direct Fired MAU, CAV Direct Fired MAU, VAV
H5081* H10030* H10445* N-H5081* N-H10030*
$0.40 $0.65 $0.25 $0.30 $0.40
Direct Fired MAU, VAV Replacing Direct Fired CAV Unit
Direct Fired MAU, CAV Direct Fired MAU, VAV
Direct Fired MAU, VAV Instead of Direct Fired CAV Unit
N-H10445 $0.20
Complete Table A1 for Code H5081 and Table A2 for Codes H10030 and H10445 on the Supplemental Data Sheet.