D ENERGY RECOVERY VENTILATOR (ERV) — REBATE CODE: H2314, H5082

PAGE 21

COOLING SYSTEM EFFICIENCY (KW/TON OR EER, 2 DECIMALS)

HOURS OF OPERATION (HRS/WK)

SUPPLY AIRFLOW (AHRI LISTED CFM)

AHRI NET TOTAL WINTER EFFECTIVENESS %

AHRI NET TOTAL SUMMER EFFECTIVENESS %

HEATING SYSTEM EFFICIENCY (%)

EQUIP #

(Example) ERV 1

60 hrs/wk

2,000

81%

77%

80%

1.20 kW/ton

E ADVANCED ROOFTOP UNIT CONTROLLERS — REBATE CODE: H3964

PAGE 23

NOMINAL COOLING CAPACITY (TONS, 2 DECIMALS)

WEEKDAY OPEN / CLOSE TIMES

SATURDAY OPEN / CLOSE TIMES

SUNDAY OPEN / CLOSE TIMES

DCV ENABLED? (Y/N)

ECONOMIZER OPERATIONAL? (Y/N)*

TOTAL VARIABLE FAN HP

HEATER TYPE (NATURAL GAS OR ELECTRIC)

EQUIP #

(Example) RTU 1

15.00

Natural Gas

5

Yes

Yes

7 AM / 9 PM 8 AM / 10 PM 11 AM / 7 PM

If DCV Enabled is “No”, the Advanced Rooftop Unit Controller measure is ineligible.

F1 DEMAND CONTROLLED VENTILATION (DCV) — REBATE CODE: H2853 (DCV FOR MULTIPLE ZONE) PAGE 24 • For the “New Min Outside Air Flow” column, enter CFM of occupant portion of the minimum outside air reduced when not in economizer mode, not total CFM provided by the AHU or RTU. At a minimum, the occupant portion of the outside airflow should be set to the average number of occupants in the zones served by the AHU/RTU multiplied by 7.5 CFM per occupant (current code minimum). • See Chapter SPS 364, Heating, Ventilating, and Air Conditioning at https://docs.legis.wisconsin.gov/code/admin_code/sps/ safety_and_buildings_and_environment/361_366/364 .

(A) EXISTING MIN OUTSIDE AIR FLOW (CFM)

(B) NEW MIN OUTSIDE AIR FLOW (CFM)

OUTSIDE AIR FLOW REDUCED (CFM) (A-B)

SPACE COOLING (Y/N)

SPACE HEATING EFF (%)

AREA SERVED TYPE

AHU COOLING SIZE (TONS)

HOURS OF OPERATION/ WEEK

EQUIP #

(Example) RTU 1

Yes

83%

Office

12

60

5,000

3,000

2,000

F2 DEMAND CONTROLLED VENTILATION (DCV) — REBATE CODE: H3266 (DCV FOR SINGLE ZONE)

PAGE 24

EXISTING AHU CONTROLS (NO SETBACK, EMS/T-STAT)

SPACE COOLING (Y/N)

AHU COOLING SIZE (TONS)

EXISTING ECONOMIZER (DB, ENTHALPY)

AREA SERVED TYPE

AREA SERVED (SQ FT)

EQUIP #

(Example) RTU 1

Yes

Office

12.00

10,000

DB

T-stat

G GUEST ROOM ENERGY MANAGEMENT CONTROLS — REBATE CODE: H2374

PAGE 24

COOLING EFFICIENCY (EER, COP, OR KW/TON)

COOLING SYSTEM SOURCE

COOLING CAPACITY PER ROOM (TONS)

HEATING EFFICIENCY (% OR COP)

HEATING SYSTEM SOURCE

HEATING CAPACITY PER ROOM (MBH)

HVAC SYSTEM TYPE

# OF ROOMS

(Example) Fan Coil Unit

10

1.2 kW/ton Air-Cooled Chiller

0.75

90%

Boiler

10

10