DEMAND CONTROL VENTILATION (DCV) Requirements:
• Complete Table G of the “2026 HVAC Rebate Requirements and Supplemental Data Sheet” for the measure code H2853 listed below. Complete Table H of the "2026 HVAC Rebate Requirements and Supplemental Data Sheet" for the measure code H3266 listed below. • For air handling units (AHU) and rooftop units (RTU), DCV controls must measure CO 2 levels in the conditioned space and provide the code required minimum level of outside air without over-ventilating. Sensors should be wall-mounted at an appropriate height within the space. Sensors may be installed in return air ductwork only if space mounting is not possible and the return duct serves a single zone. • DCV for AHU measure is intended for central air handling units which have multiple individually controlled spaces and will require a CO 2 sensor in each occupied zone served by the AHU. Unit ventilators may be eligible for the multiple zone rebate (MMID 2853) as long as all other requirements are met, including a functioning economizer. • If system is custom-built using a CO 2 sensor and the buildings, existing automation system, provide a copy of the control sequence that was programmed into the building automation system.
CO 2
Measure Description
Code
Rebate
Unit
DCV for Multiple Zone RTU/AHU/Unit Ventilator
H2853* H3266*
$0.50
CFM Reduced
DCV for Single Zone RTU/AHU
$650 RTU/AHU
*Supplemental data sheet needed. Rebate amount is limited to 50% of the project cost, including equipment and external labor.
PRO TIP Spaces with large variations in occupancy are great candidates for DCV. Controls allow the HVAC system to determine the proper level of ventilation without creating unnecessary heating and cooling loads.
PRO TIP CO 2 sensors with a 2% accuracy rating are recommended for long-term reliability.
PARKING GARAGE VENTILATION CONTROLS Requirements:
• Complete Table I of the “HVAC Rebate Requirements and Supplemental Data Sheet” for this measure. • “Garage Size (sq ft),” “Heating System Capacity,” “Heating System Efficiency,” and “Heating Set Point” are only required for heated garages. • Install carbon monoxide (CO) controls to control parking garage exhaust fans that meet all state and local codes. • Current system must run 24/7. • Heated garages must be heated by either natural gas furnaces, natural gas unit heaters, or hot water/steam foam on an on-site natural gas boiler. Garages heated by municipal steam systems (i.e., “city steam”) are not eligible.
Measure Description
Code H4837* H3493*
Rebate
Unit
Parking Garage Ventilation Controls
$120 $250
System System
Parking Garage Ventilation Controls With Heating
*Supplemental data sheet needed.
SMART THERMOSTATS Requirements: • Smart thermostats must replace a standard (manual) or programmable thermostat. • Smart thermostats must be certified as an ENERGY STAR smart thermostat or on focusonenergy.com/qpls in the Focus on Energy business rebates qualified products list. • Smart thermostats must be purchased at a retailer to qualify for this rebate. Proof of purchase will be required. • Smart thermostats purchased through the Focus on Energy Online Marketplace are ineligible for this rebate. • Instant discounts are available for contractor-supplied and installed smart thermostats. Refer to focusonenergy.com/instantdiscounts for more information.
Measure Description
Code
Rebate
Unit
Smart Thermostat Controlling Electric Heat Smart Thermostat Controlling Natural Gas Heat
H10053 H10054
$50 $50 $50
Thermostat Thermostat Thermostat
Smart Thermostat Controlling Natural Gas Heating and Electric Cooling H10052