COMPRESSED AIR AND VACUUM PUMPS
COMPRESSED AIR LEAK SURVEY AND REPAIR Requirements: • Rebate is per horsepower (hp) of connected air compressors in the system. Do not include the hp of any dedicated backup air compressors in the total connected hp. • Customer must repair at least one leak for every five connected compressor hp. If less than one leak per every five hp is identified, then all leaks identified must be repaired. In the case where all identified leaks must be repaired, customer may provide written explanation for a leak that cannot be repaired and may still qualify for the rebate. • Leaks must be repaired before application is submitted and Focus on Energy must receive the application within 120 days of leak survey completion date. • Customers may leave a physical leak tag in place for at least two months or keep an electronic log that documents the leak details (such as location, size, repair date, etc.) to allow Focus on Energy to verify leak repairs if needed. • This rebate is only available once per 12 month period (based on latest repair date), per customer site. • A leak log in the form of a spreadsheet must be submitted with the completed rebate application. The following data must be recorded for each leak: tag number, location, description, leak dB reading, estimated cost of leak ($/year), and repaired (yes/no). • Rebate is eligible for up to 100% of survey and repair costs with a maximum rebate of $5,000 per year. Application Measure Description Code Rebate Unit Retrofit Leak Survey and Repair PS4766* $6 hp *Complete Table A on the Supplemental Data Sheet. VSD AIR COMPRESSORS Requirements: • Submit manufacturer specification sheets and/or a CAGI sheet at anticipated operating pressure for equipment or compressor installed.
• Must be variable speed rotary vane compressor or variable speed screw compressor to be eligible. • This is for new VSD compressors only; adding a VSD to an existing compressor does not qualify.
• Replacing an old VSD compressor with a new (same size) VSD compressor does not qualify. However, replacement of an old VSD compressor with a new, larger VSD compressor is eligible for the increase in hp over the old compressor. For example, if a 50 hp VSD compressor is replaced with a 75 hp VSD compressor, the 25 hp increase in capacity would be eligible for rebates. • Limited to one VSD compressor per compressed air system. Any exceptions due to large load variations within a system or adding compressor capacity to a system require pre-approval before you start your project. • Replaced equipment must be removed. If an old compressor replaced by a VSD compressor remains connected as emergency backup, by signing the application, the customer is attesting that the old compressor will be used only in case of emergency and will rarely (if ever) operate. Application Measure Description Code Rebate Unit Retrofit VSD Compressor replacing Non-VSD Compressor PS2196* $75 hp New Construction VSD Compressor instead of Non-VSD Compressor N-PS2196* $75 hp * Complete Table B1 and B2 on the Supplemental Data Sheet.
PLEASE NOTE
12
Powered by FlippingBook