REFRIGERATION CONTROLS
General Requirements: Rebates are available for installing controls on non-self-contained refrigeration equipment, either existing equipment or in conjunction with new equipment listed on this page. Controls costs must be itemized separately on invoice. Rebates are not available for replacing existing controls.
ANTI-SWEAT HEATER CONTROLS Requirements:
• Controls must be designed specifically as anti-sweat (anti-condensate) heater controls and must sense the relative humidity in the air outside of the display case and turn off the anti-sweat heaters at low humidity conditions. • Controls may be programmed in a larger store system, such as PMAC or EMS. If so, please include the system
information along with the options for anti-sweat heater controls denoted. • Must control heaters on rail (mullion) and door, if equipped with heater. Application Measure Description Code
Rebate
Unit Door Door
Anti-Sweat Heater Controls, Freezer Case Anti-Sweat Heater Controls, Refrigerated Case
R5439 R5440
$40 $40
Retrofit
EVAPORATOR FAN SPEED CONTROLS Requirements: • By signing the application, customer agrees the cooler/freezer space has been properly tested to avoid hot spots away from thermostat during low-speed fan operation. Application Measure Description Code Rebate Unit
Evaporator Fan Control for Walk-in Cooler/Freezer
R2269
Motor
$25 $30 $15 $16
Retrofit
Evaporator Fan Control for Reach-in Cooler/Freezer
R4759
Motor Motor Motor
New Construction Evaporator Fan Control for Walk-in Cooler/Freezer New Construction Evaporator Fan Control for Reach-in Cooler/Freezer
N-R2269 N-R4759
DEMAND DEFROST CONTROLS Requirements: • Rebate is based on kW of electric defrost controlled. Please include the evaporator make and model information, along with the defrost controls make and model information on the application, invoice, or manufacturer specification sheet. • Electric defrost heater controls in coolers may be eligible for a custom incentive. Application Measure Description Code Rebate Unit Retrofit Freezer Demand Defrost R4758 $20 kW Controlled New Construction Freezer Demand Defrost N-R4758 $15 kW Controlled FLOATING HEAD PRESSURE CONTROLS Requirements: • Controls must monitor and modulate refrigerant line pressure based on ambient temperature and/or atmospheric conditions. • Controls on HVAC and ammonia refrigeration systems are ineligible. • In the “# of Units” column on the application, enter the refrigeration compressor horsepower (hp) controlled with floating head pressure controls. Include supporting documentation such as compressor make and model, spec sheet, or nameplate photos to confirm hp. • If the refrigeration system hp is unavailable, convert the low temperature (LT) and medium temperature (MT) systems’ rated cooling capacity in BTU/h using the following factors:
• LT hp = LT compressor capacity (BTU/h)/6,000 • MT hp = MT compressor capacity (BTU/h)/8,700
Application
Measure Description
Code R4360
Incentive
Unit
Retrofit
Refrigeration Controls, Floating Head Pressure
$25
hp
11