2026 Process Systems Catalog

C DEWPOINT DEMAND CONTROLS FOR DESICCANT DRYERS – REBATE CODE: PS4363

PAGE 14

• For “air compressor type,” enter “single-acting reciprocating,” “double-acting reciprocating,” “single stage rotary screw,” “two-stage rotary screw,” “oil-free rotary screw,” “centrifugal,” or “other”. • For “air compressor control type,” enter “variable speed drive,” “load/unload,” “inlet modulating damper,” or “variable displacement”. • For “desiccant dryer type,” enter “heatless,” “heated,” or “blower purge”

ANNUAL HOURS OF COMPRESSOR OPERATION AIR COMPRESSOR TYPE

AIR COMPRESSOR CONTROL TYPE Variable Speed Drive

DESICCANT DRYER TYPE

(Example) 4,200

Variable Speed Drive

Heated Dryer

D EFFICIENT DESICCANT DRYERS – REBATE CODE: PS5441, PS5442, PS5443

Page 14

• For “air compressor type,” enter “single-acting, air-cooled reciprocating,” “double-acting, water-cooled reciprocating,” “single stage, lubricant- injected rotary screw,” “two-stage, lubricant-injected rotary screw,” “lubricant-free rotary screw,” “centrifugal,” or “other.” HOURS OF OPERATION AIR COMPRESSOR TYPE DRYER CAPACITY (CFM) (Example) 6,240 Single-stage, lubricant-injected rotary screw 1,500 ww

E

COMPRESSED AIR STORAGE – REBATE CODE: PS5444

PAGE 15

• For existing compressor Hp and airflow, enter the Hp and airflow for the lead and trim air compressors that normally run during plant operation; do not include dedicated backup compressors. • For “control method,” enter “load/no load,” or “modulating with blowdown”. AIR COMPRESSOR EXISTING STORAGE

(D) CAPACITY (GAL/CFM) (C + B) **QUALIFIES IF ≤ 1**

(F) IMPROVED STORAGE CAPACITY (GAL/CFM) (C + E) + B **QUALIFIES IF ≥ 3*

(C) TANK SIZE (GAL)

(E) STORAGE ADDED (GAL)

(A) SIZE (HP)

(G) REBATE (A X $35/HP)

HOURS OF OPERATION

CONTROL METHOD

(B) AIRFLOW

(Example) 6,240

Load/No Load

100

460

400

0.87 GAL/CFM

1,100

3.26 GAL/CFM

$3,500

F COMPRESSED AIR LOAD SHIFTING – REBATE CODE: PS2848

PAGE 16

EXISTING AIR COMPRESSOR(S)

REPLACEMENT TECHNOLOGY

HOURS OF OPERATION

TOTAL HP

AIRFLOW (CFM) @ PRESSURE (PSI)

SHORT DESCRIPTION

SHORT DESCRIPTION INAPPROPRIATE USE AIRFLOW (CFM)

Hp

450 CFM @ 100 psi

(Example) 4,200 100

Blow-off with open tubes

85 CFM

Air knife with blower

2 hp

G BOILER COMBUSTION UPGRADES – REBATE CODE: PS4760, PS4761, PS4762, PS5238

PAGE 17

PRE-RETROFIT BOILER EFFICIENCY

ANNUAL HOURS OF OPERATION

BOILER LOAD FACTOR

(Example) 81.2%

6,000

85%

H1 VARIABLE TORQUE VFD - REBATE CODE: PS2726, PS2640, PS2641, PS2647, PS2648, PS10434, PS10436

• For the “controls before VFD,” enter “outlet control valve,” “bypass valve,” “discharge damper,” “inlet guide vanes,” “on/off,” “none,” or “other” and then describe.

EQUIPMENT OPERATING HOURS (2,000 HR/YR MIN)

HP CONTROLLED BY VFD

QTY REQUESTED REBATE (QTY X HP X REBATE)

VFD#

REBATE CODE CONTROLS BEFORE

(Example) 1

On/Off

8,400

20

3

3 X 20 X $55 = $3,300

PS2648

9

* Focus on Energy may adjust total rebate based on project caps. See measure requirements and Terms and Conditions for more information.