C DEWPOINT DEMAND CONTROLS FOR DESICCANT DRYERS – REBATE CODE: PS4363
PAGE 14
• For “air compressor type,” enter “single-acting reciprocating,” “double-acting reciprocating,” “single stage rotary screw,” “two-stage rotary screw,” “oil-free rotary screw,” “centrifugal,” or “other”. • For “air compressor control type,” enter “variable speed drive,” “load/unload,” “inlet modulating damper,” or “variable displacement”. • For “desiccant dryer type,” enter “heatless,” “heated,” or “blower purge”
ANNUAL HOURS OF COMPRESSOR OPERATION AIR COMPRESSOR TYPE
AIR COMPRESSOR CONTROL TYPE Variable Speed Drive
DESICCANT DRYER TYPE
(Example) 4,200
Variable Speed Drive
Heated Dryer
D EFFICIENT DESICCANT DRYERS – REBATE CODE: PS5441, PS5442, PS5443
Page 14
• For “air compressor type,” enter “single-acting, air-cooled reciprocating,” “double-acting, water-cooled reciprocating,” “single stage, lubricant- injected rotary screw,” “two-stage, lubricant-injected rotary screw,” “lubricant-free rotary screw,” “centrifugal,” or “other.” HOURS OF OPERATION AIR COMPRESSOR TYPE DRYER CAPACITY (CFM) (Example) 6,240 Single-stage, lubricant-injected rotary screw 1,500 ww
E
COMPRESSED AIR STORAGE – REBATE CODE: PS5444
PAGE 15
• For existing compressor Hp and airflow, enter the Hp and airflow for the lead and trim air compressors that normally run during plant operation; do not include dedicated backup compressors. • For “control method,” enter “load/no load,” or “modulating with blowdown”. AIR COMPRESSOR EXISTING STORAGE
(D) CAPACITY (GAL/CFM) (C + B) **QUALIFIES IF ≤ 1**
(F) IMPROVED STORAGE CAPACITY (GAL/CFM) (C + E) + B **QUALIFIES IF ≥ 3*
(C) TANK SIZE (GAL)
(E) STORAGE ADDED (GAL)
(A) SIZE (HP)
(G) REBATE (A X $35/HP)
HOURS OF OPERATION
CONTROL METHOD
(B) AIRFLOW
(Example) 6,240
Load/No Load
100
460
400
0.87 GAL/CFM
1,100
3.26 GAL/CFM
$3,500
F COMPRESSED AIR LOAD SHIFTING – REBATE CODE: PS2848
PAGE 16
EXISTING AIR COMPRESSOR(S)
REPLACEMENT TECHNOLOGY
HOURS OF OPERATION
TOTAL HP
AIRFLOW (CFM) @ PRESSURE (PSI)
SHORT DESCRIPTION
SHORT DESCRIPTION INAPPROPRIATE USE AIRFLOW (CFM)
Hp
450 CFM @ 100 psi
(Example) 4,200 100
Blow-off with open tubes
85 CFM
Air knife with blower
2 hp
G BOILER COMBUSTION UPGRADES – REBATE CODE: PS4760, PS4761, PS4762, PS5238
PAGE 17
PRE-RETROFIT BOILER EFFICIENCY
ANNUAL HOURS OF OPERATION
BOILER LOAD FACTOR
(Example) 81.2%
6,000
85%
H1 VARIABLE TORQUE VFD - REBATE CODE: PS2726, PS2640, PS2641, PS2647, PS2648, PS10434, PS10436
• For the “controls before VFD,” enter “outlet control valve,” “bypass valve,” “discharge damper,” “inlet guide vanes,” “on/off,” “none,” or “other” and then describe.
EQUIPMENT OPERATING HOURS (2,000 HR/YR MIN)
HP CONTROLLED BY VFD
QTY REQUESTED REBATE (QTY X HP X REBATE)
VFD#
REBATE CODE CONTROLS BEFORE
(Example) 1
On/Off
8,400
20
3
3 X 20 X $55 = $3,300
PS2648
9
* Focus on Energy may adjust total rebate based on project caps. See measure requirements and Terms and Conditions for more information.