2024 Process Systems Catalog

K ENERGY-EFFICIENT DRYCOOLER FOR DATA CENTER AND TELECOM – INCENTIVE CODE: PS2305

PAGES 22

CRAC UNIT COOLING EFFICIENCY

CRAC UNIT FAN QTY & HP

DRYCOOLER GLYCOL PUMP QTY & HP

DRYCOOLER FAN QTY & HP

(Example) 1.25 kW/ton

1 @ 10 HP

1 @ 2 HP

4 @ 1 HP

L DATA CENTER AND TELECOM EFFICIENT UPS AND RECTIFIER – INCENTIVE CODE: PS4777, PS4778

PAGES 23

OLD UPS / RECTIFIER EFFICIENCY (%)

NEW UPS / RECTIFIER EFFICIENCY (%)

TYPE OF COOLING SYSTEM DX CRAC Units

COOLING EFFICIENCY AND UNITS

IT EQUIPMENT LOAD (KW)

(Example) 52 kW

82%

94%

1.1 kW/ton

M

RADIANT HEATER BANDS – INCENTIVE CODE: PS2490

PAGE 24

ANNUAL HOURS OF OPERATION

VOLTAGE (IF AVAILABLE)

AVERAGE AMPS BEFORE (IF AVAILABLE)

AVERAGE AMPS AFTER (IF AVAILABLE)

INSTALLED KW OF EXISTING HEATER BANDS

REQUESTED INCENTIVE*

(Example) 4,000

460

56.5

48

45

$2,700

N

PRESSURE SCREEN ROTOR – INCENTIVE CODE: PS2496

PAGE 25

HOURS OF OPERATION

VOLTAGE (IF AVAILABLE)

AVERAGE AMPS BEFORE (IF AVAILABLE)

AVERAGE AMPS AFTER (IF AVAILABLE)

REQUESTED INCENTIVE*

HP INSTALLED

(Example) 6,000

480

150

100

150

$6,000

O REPULPER ROTOR AND EXTRACTION PLATE – INCENTIVE CODE: PS2538, PS5210

PAGE 25

HOURS OF OPERATION

VOLTAGE (IF AVAILABLE)

AVERAGE AMPS BEFORE (IF AVAILABLE)

AVERAGE AMPS AFTER (IF AVAILABLE)

REQUESTED INCENTIVE*

MEASURE

HP INSTALLED

(Example) Repulper Rotor

8,000

2,300

110

90

500

$15,000

P

SPLINE ROTOR UPGRADE – INCENTIVE CODE: PS4764

PAGE 26

AVERAGE CONNECTED REFINER HP

REFINER HOURS OF OPERATION

REQUESTED INCENTIVE*

REFINER HP

% LOAD ON REFINER

(Example) 500

85%

425

8,400

$12,500

Q HIGH EFFICIENCY SIDE ENTRY AGITATOR – INCENTIVE CODE: PS4763

PAGE 26

AVERAGE CONNECTED REFINER HP

MOTOR HOURS OF OPERATION

REQUESTED INCENTIVE*

AGITATOR MOTOR HP

% MOTOR LOAD ON AGITATOR

(Example) 100

85%

85

8,400

$3,000

R INDUSTRIAL HIGH FREQUENCY BATTERY CHARGERS – INCENTIVE CODE: PS4765

PAGE 27

HOURS PER YEAR EACH CHARGER IS IN MAINTENANCE MODE (WHEN A FULLY CHARGED BATTERY IS CONNECTED)

HOURS PER YEAR EACH CHARGER IS IN NO BATTERY MODE (WHEN NO BATTERY IS CONNECTED)

HOW DRAINED ARE THE BATTERIES WHEN PLUGGED INTO CHARGERS?

NUMBER OF CHARGES PER WEEK PER CHARGER

(Example) 80%

7

365 hrs/year

2,920 hrs/yr = 8 hrs/day * 365 days/yr)

S

PROCESS EXHAUST FILTRATION – INCENTIVE CODE: PS3244

PAGE 28

REQUESTED INCENTIVE*

ANNUAL HOURS OF OPERATION DAYS/WEEK OPERATION

HEATING SYSTEM EFFICIENCY REDUCTION IN MAKE-UP CFM

(Example) 6,000

5

95%

30,000

$18,000

* Focus on Energy may adjust total incentive based on project caps. See measure requirements and Terms and Conditions for more information.

9