COMPRESSED AIR STORAGE – INCENTIVE CODE: PS5444
PAGE 15
AIR COMPRESSOR
EXISTING STORAGE
(D) CAPACITY (GAL/CFM) (C + B) **QUALIFIES IF ≤ 1**
(F) IMPROVED STORAGE CAPACITY (GAL/CFM) (C + E) + B **QUALIFIES IF ≥ 3*
(C) TANK SIZE (GAL)
(E) STORAGE ADDED (GAL)
(G) INCENTIVE (A X $20/HP)
HOURS OF OPERATION
CONTROL METHOD
(A) SIZE (HP)
(B) AIRFLOW
(Example) 6,240 Load/No Load
100
460
400
0.87 GAL/CFM
1,100
3.26 GAL/CFM
$2,000
F
COMPRESSED AIR LOAD SHIFTING – INCENTIVE CODE: PS2848
PAGE 17
EXISTING AIR COMPRESSOR(S)
REPLACEMENT TECHNOLOGY
INAPPROPRIATE USE AIRFLOW (CFM)
HOURS OF OPERATION
AIRFLOW (CFM) @ PRESSURE (PSI) 450 CFM @ 100 psi
COMPLETION DATE (EST.)
TOTAL HP
SHORT DESCRIPTION
SHORT DESCRIPTION HP
Blow-off with open tubes
85 CFM Air knife with blower
2 HP
(Example) 4,200
100
6/15/24
G BOILER COMBUSTION UPGRADES – INCENTIVE CODE: PS4760, PS4761, PS4762, PS5238
PAGE 19
PRE-RETROFIT BOILER EFFICIENCY
ANNUAL HOURS OF OPERATION
BOILER LOAD FACTOR
(Example) 81.2%
6,000
85%
H1 VARIABLE TORQUE VFD, VSD VACUUM PUMP ≤30 HP – INCENTIVE CODE: PS4361 VARIABLE TORQUE VFD - INCENTIVE CODE: PS2726, PS2640, PS2641, PS2647, PS2648 VFD# VFD APPLICATION CONTROLS BEFORE EQUIPMENT OPERATING HOURS (2,000 HR/YR MIN) HP CONTROLLED BY VFD
PAGE 12 OR 20
REQUESTED INCENTIVE* (QTY X HP X INCENTIVE)
QTY
(Example) Fan 1
Process Fan
Inlet Guide Vanes
6,000
100
1
$4,000
H2 VARIABLE TORQUE VFD - INCENTIVE CODE: PS2726, PS2640, PS2641, PS2647, PS2648 (IF HP > 500)
% Load Running % of Time Running
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
I1 CONSTANT TORQUE VFD, VSD VACUUM PUMP, ≤30 HP – INCENTIVE CODE: PS4362
PAGE 12 OR 21
CONSTANT TORQUE VFD – INCENTIVE CODE: PS3280
COMPLETE FOR MANUAL CONTROL
EQUIPMENT OPERATING HOURS (2,000 hr/yr min)
REQUESTED INCENTIVE* (QTY X HP X INCENTIVE)
ANNUAL HOURS AT 100%
ANNUAL HOURS AT 80%
ANNUAL HOURS AT 60%
ANNUAL HOURS AT 40%
ANNUAL HOURS AT 20%
HP CONTROLLED BY VFD
VFD APPLICATION
CONTROLS BEFORE
CONTROLS AFTER
VFD#
QTY
(Example) Mixer 1
Mixer
On/Off
Manual
1,000 500 2,000 2,000 0
5,500
25
1
$875
I2 CONSTANT TORQUE VFD – INCENTIVE CODE: PS3280 (IF HP > 500)
% Load Running % of Time Running
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
J DATA CENTER AND TELECOM AIR SIDE ECONOMIZER – INCENTIVE CODE: PS4776
PAGES 22
CHILLED WATER SUPPLY TEMPERATURE (IF COOLING SYSTEM IS CHILLER) (°F)
ECONOMIZER SHUTOFF TEMPERATURE (°F)
COOLING TOWER FAN QTY & HP (IF APPLICABLE)
COOLING TOWER WATER PUMP HP (IF APPLICABLE)
SUPPLY AIR TEMPERATURE (°F)
COOLING SYSTEM AHRI EFFICIENCY (EER)
CHILLER COMPRESSOR TYPE (IF APPLICABLE)
(Example) 65°F
60°F
12 EER
44°F
Scroll
3 @ 20 HP
7
* Focus on Energy may adjust total incentive based on project caps. See measure requirements and Terms and Conditions for more information.