2024 HVAC Catalog

NEW CONSTRUCTION AND MAJOR RENOVATIONS Measure Description

Code

Incentive

Unit

$20/ton + $3/ ton per 1.0 IEER over min. $20/ton + $3/ ton per 1.0 IEER over min. $20/ton + $3/ ton per 1.0 IEER over min. $20/ton + $3/ ton per 1.0 IEER over min. $20/ton + $3/ ton per 1.0 IEER over min. $20/ton + $3/ ton per 1.0 IEER over min. $20/ton + $3/ ton per 1.0 IEER over min.

DX Cooling ≥5.42 to <11.25 tons, Min. Eff. = 16.1 IEER (additional incentive on IEER)

N-H4368*

Ton

DX Cooling ≥11.25 to <20.00 tons, Min. Eff. = 15.4 IEER (additional incentive on IEER)

N-H4369*

Ton

DX Cooling ≥20.00 to <63.33 tons, Min. Eff. = 14.3 IEER (additional incentive on IEER)

N-H4370*

Ton

DX Cooling ≥63.33 tons, Min. Eff. = 9.7 EER and 11.4 IEER (additional incentive on IEER)

N-H4371*

Ton

Air Source Heat Pump ≥5.42 to <11.25 tons, Min. Eff. = 15.1 IEER (additional incentive on IEER)

N-H10025

Ton

Air Source Heat Pump 11.25 to <20.00 tons, Min. Eff. = 14.5 IEER (additional incentive on IEER)

N-H10026

Ton

Air Source Heat Pump ≥20.00 to <63.33 tons, Min. Eff. = 13.5 IEER (additional incentive on IEER)

N-H10027

Ton

* Supplemental Data Sheet needed

SPLIT SYSTEM AIR CONDITIONING – CONDENSING UNIT ONLY Requirements:

• Complete Table B3 of the “HVAC Incentive Catalog Supplemental Data Sheet” for this measure. • For the “Delta Efficiency” column, use “AHRI Rated Full Load Efficiency” – “Min. Eff. To Qualify.”

• For the “Incentive Rate” column, use “Additional Incentive” + “Base Incentive.” • For the “Total Incentive” column, use “AHRI Rated Capacity” x “Incentive Rate.” • Only complete one line of supplemental data sheet if multiple of the exact same model number were installed.

• Incentive is for the installation of high-efficiency condensing units for use in split system air conditioning systems. The base incentive rate for meeting the minimum efficiency is $20/ton, with an additional $5/ton incentive for each 1.0 EER that the cooling system exceeds the minimum efficiency. For example, a 15.00 ton, 12.1 EER condensing unit would be eligible for a $20/ton + (0.6 EER over minimum x $5/ton) = $23/ton incentive. • For assistance with determining equipment eligibility and incentive rate, look for the Cooling Eligibility Screening Tool at focusonenergy.com/catalogs . • Incentives are for standard HVAC applications only. Condensing units used for industrial process cooling, data centers, ice rinks, and refrigerated warehouses may qualify for a custom incentive. • Rated AHRI efficiency must meet or exceed minimum ratings shown for EER. AHRI-verified cooling capacity and EER will be used to calculate the incentive. • Equipment ≥20.83 tons is not listed in the ahridirectory.org. For this equipment, provide manufacturer performance data sheet that indicates ratings are “at AHRI conditions”. • For multiple of the exact same model number, complete the Incentive Application as follows: enter qty @ tons each in the # of Units column (example: 3 @ 15.00). • Condensing units may be included in the Split and Packaged Systems Incentives (H4368, H4369, H4370, H4371) or the Condensing Unit Only Incentives (H3909), but not both. EQUIPMENT UPGRADES AND RETROFITS Measure Description Code Incentive Unit

$20/ton + $5/ton per 1.0 EER over min.

Split System A/C Condensing Unit Only, ≥11.25 tons, ≥11.5 EER

H3909*

Ton

* Supplemental Data Sheet needed

PRO TIP Additional system strategies include variable speed fans and compressor controls to more effectively use the refrigerant and modulate the temperature and amount of cooled air supplied to the space. See demand controlled ventilation (DCV) and smart thermostats for additional savings opportunities.