PACKAGED TERMINAL HEAT PUMPS (PTHP) Requirements: • Unit must be AHRI listed as a Commercial PTHP. • Eligibility for PTHP measures is based on customer having an eligible electric provider. • Must replace or be instead of a Packaged Terminal Air Conditioner (PTAC). Replacement of existing PTHP does NOT qualify.
• Window and through-the-wall air conditioners/heat pumps do not qualify. • The equipment size category (BTUh) is the cooling capacity value of the unit. • Must meet both heating and cooling specifications for the equipment size category. • All efficiency ratings will be verified using the AHRI database (ahridirectory.org). EQUIPMENT UPGRADES AND RETROFITS Measure Description
Code
Incentive
Unit
PTHP <8,000 BTUh, ≥10.7 EER, and ≥3.1 COP
H2699
$75
PTHP
PTHP 8,000-9,999 BTUh, ≥10.4 EER, and ≥3.0 COP
H2702
$75
PTHP
PTHP 10,000-12,999 BTUh, ≥9.9 EER, and ≥2.9 COP
H2701
$75
PTHP
PTHP ≥13,000 BTUh, ≥9.3 EER, and ≥2.9 COP
H2700
$75
PTHP
NEW CONSTRUCTION AND MAJOR RENOVATIONS Measure Description
Code
Incentive
Unit
PTHP <8,000 BTUh, ≥12.7 EER, and ≥3.1 COP
N-H2699
$65
PTHP
PTHP 8,000-9,999 BTUh, ≥12.1 EER, and ≥3.0 COP
N-H2702
$65
PTHP
PTHP 10,000-12,999 BTUh, ≥10.9 EER, and ≥2.9 COP
N-H2701
$65
PTHP
PTHP ≥13,000 BTUh, ≥10.3 EER, and ≥2.9 COP
N-H2700
$65
PTHP
DIRECT-FIRED MAKE-UP AIR UNITS Requirements:
• Complete Table A1 for Code H5081 and A2 for Code H10030 of the “HVAC Incentive Catalog Supplemental Data Sheet” for these measures. • Incentive is available for upgrading (or installing instead of) indirect fired make-up air units or rooftop units which are approximately 80% efficient.
• Replacement of an existing direct-fired make-up air unit is not eligible. • Replacement of electric or hydronically heated make-up air is not eligible. • Replacement of a variable air volume make-up air unit is not eligible. • Intended for spaces with high ventilation or exhaust loads. • Installation and operation must follow all applicable building code requirements. • Direct fired make-up air unit must serve an occupied space for at least 500 hours per year. • Variable air volume make-up units (H10030) are not eligible for VFD incentives. EQUIPMENT UPGRADES AND RETROFITS Measure Description
Code
Incentive
Unit
Direct Fired Make-up Air Unit, Constant Air Volume
H5081*
$0.25
CFM
Direct Fired Make-up Air Unit, Variable Air Volume
H10030*
$0.35
CFM
* Supplemental Data Sheet needed
NEW CONSTRUCTION AND MAJOR RENOVATIONS Measure Description
Code
Incentive
Unit
Direct Fired Make-up Air Unit, Constant Air Volume
N-H5081*
$0.15
CFM
Direct Fired Make-up Air Unit, Variable Air Volume
N-H10030*
$0.25
CFM
* Supplemental Data Sheet needed
16