General Requirements: Incentives are available for installing lighting controls which meet the requirements as described in each of the sections below. Controls may be installed on existing lighting equipment or in conjunction with new equipment listed throughout the catalog. Sensors may control more than one fixture. Control costs should be itemized separately on invoice. For controls that are integral to new fixtures, provide supporting documentation to show the cost of the fixtures without controls included.

DAYLIGHTING CONTROLS Requirements:

• Complete Table B of the "Lighting Incentive Catalog Supplemental Data Sheet" for this measure. • Must be step dimmed with at least one level in addition to full power and off or continuous dimming controls. • Specification sheets for controls and fixtures controlled, along with a floor plan showing window/skylight locations and fixtures which are considered to be in the daylit zone, must be submitted with the application. • Inventory of fixtures controlled (including quantity, fixture type, and number of lamps per fixture) by space type or lighting diagram must be submitted with the application. • For retrofit situations where specification sheets are not available for existing fixtures, program default wattages will be used for calculating incentives. Reference page 9 for default wattage table or contact Focus on Energy to obtain a system wattage not listed. • Daylighting controls may be combined with additional incentives for occupancy sensors. EQUIPMENT UPGRADES AND RETROFITS Measure Description Code Incentive Unit Daylighting Controls L3406* $0.10 Watt Controlled * Supplemental Data Table needed HIGH AND LOW BAY CONTROLS Requirements: • Complete Table B of the "Lighting Incentive Catalog Supplemental Data Sheet" for these measures. • Sensors must be ultrasonic, passive infrared, microwave, or dual technology and rated for controlling high bay fixtures. • May be high/low or on/off controls as listed below. • Eligible sensors include high wall, ceiling, or fixture mounted sensors designed for controlling fixtures in high- or low-bay applications. • Socket-based occupancy sensors do not qualify. • Timers do not qualify for prescriptive incentives, but may be eligible for custom incentives.

• Upgrading existing high-bay controls are not eligible. EQUIPMENT UPGRADES AND RETROFITS Measure Description

Code L5061*

Incentive

Unit

On/Off Occupancy Control

$0.10

Watt Controlled

Bi-Level Occupancy Control

L5062*

$0.10

Watt Controlled

* Supplemental Data Table needed

EXAMPLE Lighting Controls Use this example when applying for lighting controls. Reference this table when filling out Supplemental Data Table B.

(C) INCENTIVE PER WATT CONTROLLED ($/WATT CONTROLLED)

(A) WATTAGE PER FIXTURE

(B) QUANTITY OF FIXTURES

REQUESTED INCENTIVE (A X B X C)

INCENTIVE CODE

FIXTURE DESCRIPTION

LOCATION

Office

L3406

New 2x4 LED troffers, 45W each

45

74

$0.10

$333

Warehouse

L5062

Existing 175W LED high bays

175

30

$0.10

$525