2024 Lighting Catalog

LIGHTING CONTROLS COMPREHENSIVE LIGHTING SOLUTIONS

FIXTURE OR RETROFIT KIT UPGRADE WITH CONNECTED CONTROLS Requirements: • All projects must be preapproved. Call 800.762.7077 or contact your Energy Advisor before you start your project. Pre-approval is considered complete once an incentive agreement is signed by the customer and returned to Focus on Energy. • Documentation required for pre-approval: • Proposal detailing existing and proposed fixture type(s), quantities and model numbers with options. • Proposed control system specifications. • Existing and proposed footcandles (either measured or calculated) at working surface for space type representing the most square footage. • Completed CLS workbook. Download a copy at focusonenergy.com/catalogs . • New fixtures/retrofit kits must be ENERGY STAR certified or DLC SSL QPL listed (TRT V5.0 or higher). • New Equipment wattage should reference the DesignLights Consortium® (DLC) Solid State Lighting (SSL) Qualified Product List (QPL) listed (TRT V5.0 or higher) performance data (Reported or Tested), ENERGY STAR® certificate rated wattage, or specification sheet wattage for the installed model. • Control systems must be DLC NLC QPL listed (NLC5 or higher) and have the following Networked Lighting Controls capabilities set up and operational for individual fixtures: • Occupancy sensing. • Zoning. • Individual Addressability. • All installations are expected to meet current IESNA recommendations for delivered light level and uniformity. Compliance is the responsibility of the installer/designer. • Customers can apply for either a fixture or retrofit kit upgrade (see L5029 on page 18) or upgrade with connected controls (see table below). Specific fixtures may apply for only one option, but both measures can be used on a project if some fixtures have NLC controls and some don't. • Fixtures and retrofit kits with connected controls are eligible. Equipment is not eligible for additional fixture or retrofit kit incentives. • Lamp-only upgrades, such as TLEDs, are NOT eligible for CLS incentives. • Systems are NOT eligible for additional control incentives (i.e. daylighting, high bay, or non-high bay controls). • Interior lighting system must operate a minimum of 2,000 hours annually to be eligible. • Exterior fixtures with connected controls in new construction applications may be eligible for incentives (see L5065 – L5068 on page 23). • For facilities with large, open space (such as open-plan office space, convention center, warehouse, or manufacturing floor) containing primarily 1-for-1 upgrades with a small percentage of the fixtures being re-configured (not 1-for-1), consult your energy advisor for guidance on setting up the CLS workbook. EQUIPMENT UPGRADES AND RETROFITS Measure Description Code Incentive Unit CLS – Fixture or Retrofit Kit with Connected Controls, Interior L5031 $0.45 Watt Reduced CLS – Fixture or Retrofit Kit with Connected Controls, Exterior L5030 $0.50 Watt Reduced Incentive amount is limited to 50% of project cost, including equipment and external labor (internal labor eligible for schools and government customers).

PLEASE NOTE

28

Powered by