LED RETROFIT OF EXTERIOR 8 FOOT FIXTURES Requirements: • Retrofit kit must be replacing an 8' fixture housing 8' lamps. The new 4' lamps must be DLC listed and <24W per lamp. • 4' Tubular LED (TLED) lamps must be DLC TRT V5.0 or higher listed in one of the following primary use categories:

• Replacement Lamps (“Plug and Play”) (UL Type A). • Internal Driver/Line Voltage (UL Type B) Lamps.

• 2-lamp External Driver (UL Type C) Lamps. • 3-lamp External Driver (UL Type C) Lamps. • 4-lamp External Driver (UL Type C) Lamps. • Dual Mode Internal Driver (UL Type A or B). • Installed equipment must be a complete retrofit kit including, but not limited to sockets, socket brackets, and/or channel covers. Detail must be provided on invoicing and spec sheets. • 4' TLED lamp exterior upgrades can be found on page 27. • UL TYPE B PRODUCTS – By signing the application, customers agree that necessary steps have been taken to ensure product, luminaire, and maintenance safety. EQUIPMENT UPGRADES AND RETROFITS Measure Description Code Incentive Unit 4' 2-lamp TLED <24W replacing 8' 1-lamp T8 or T12 24 Hour: L4316 Dusk to Dawn: L4315 $12 Fixture

24 Hour: L4319 Dusk to Dawn: L4318 24 Hour: L4322 Dusk to Dawn: L4321 24 Hour: L4325 Dusk to Dawn: L4324 24 Hour: L4328 Dusk to Dawn: L4327 24 Hour: L4331 Dusk to Dawn: L4330

4' 2-lamp TLED <24W replacing 8' 1-lamp T8HO or T12HO

$12

Fixture

4’ 4-lamp TLED <24W replacing 8' 2-lamp T8 or T12

$15

Fixture

4' 4-lamp TLED <24W replacing 8' 2-lamp T8HO or T12HO

$15

Fixture

$25

Fixture

4' 2-lamp TLED <24W replacing 8' 2-lamp T8 or T12

$25

Fixture

4' 2-lamp TLED <24W replacing 8' 2-lamp T8HO or T12HO

EXTERIOR LED SIGNAGE Requirements: • Complete Table A of the "Lighting Incentive Catalog Supplemental Data Sheet" for this measure. • Must result in at least a 30% wattage reduction to be eligible. • LED upgrades from incandescent, HID, fluorescent or neon exterior commercial signage are eligible for this measure.

• Applications include, but are not limited to channel lettering, backlit displays, and menu boards. • Signs illuminated by flood fixtures should refer to flood fixture incentive offerings on page 23.

• Clear documentation (i.e. spec sheets, sign schematics, existing ballast, or transformer) of existing equipment or metering data (i.e. voltage and amperage readings) MUST be provided or measure eligibility will be subject to disqualification. For neon signs, a 60% power factor will be assumed for the neon sign transformer unless supporting documentation for a different value is provided. • Replacement lamp products that intend to use existing sockets or lamp holders MUST be reviewed by Focus on Energy prior to installation. • Incentive may be adjusted if existing ballast information is not provided. EQUIPMENT UPGRADES AND RETROFITS Measure Description Code Incentive Unit Exterior LED Signage L3904* $0.25 Watt Reduced * Supplemental Data Table needed EXAMPLE LED Exterior Signage Use this example when applying for LED Exterior Signage. Use as many lines necessary to account for all existing and proposed fixture types. Reference this table when filling out Supplemental Data Table A.

(E) WATTS REDUCED PER FIXTURE (A - C)

(A) WATTAGE OF EXISTING EQUIPMENT PER FIXTURE

(F) INCENTIVE PER WATT REDUCED ($/WATT REDUCED)

(B) QUANTITY OF EXISTING EQUIPMENT

(C) WATTAGE OF NEW EQUIPMENT PER FIXTURE

(D) QUANTITY OF NEW EQUIPMENT

TYPE OF EXISTING EQUIPMENT

REQUESTED INCENTIVE (D X E X F)

TYPE OF NEW EQUIPMENT

LOCATION

25' LED strip, 2 watts/ft

$0.25/W reduced

Exterior Signage 2L F96T12

109

1

50

1

59

$14.75

25