2024 Lighting Catalog

INTERIOR LIGHTING NEW CONSTRUCTION

LED HIGH AND LOW BAY LIGHTING Requirements: • Fixtures must be DLC SSL QPL listed (TRT V5.0 or higher) under the High-Bay or Low-Bay General Application category.

LED DOWNLIGHTS Requirements: • Fixtures must be listed on ENERGY STAR as a “Downlight Recessed,” “Downlight Solid State Retrofit,” “Downlight Surface Mount,” “Ceiling Mount”, or “LED Surface Mount Ceiling Retrofit” fixture type and be intended for commercial use. NEW CONSTRUCTION AND MAJOR RENOVATIONS Measure Description Code Incentive Unit LED Downlight Fixture instead of incandescent, CFL, or HID fixture. N-L10028 $4 Fixture • Fixtures for low-bay applications may use products that are DLC SSL QPL listed (TRT V5.0 or higher) under the “Linear Ambient” General Application category, “Fuel Pump Canopy Luminaires”, or “Parking Garage Luminaires” Primary Use Designation, if they provide sufficient lighting levels and meet the wattage limitations in the table below. • Product categories listed below do not imply equivalency - all installations are expected to meet current IESNA recommendations for delivered light level and uniformity. Compliance is the responsibility of the installer. NEW CONSTRUCTION AND MAJOR RENOVATIONS Measure Description Code Incentive Unit ≤85 Watts, Instead of 4 Lamp 4' or 2 Lamp 8' T8 or T12 N-L5460 $7 Fixture ≤180W LED, instead of 6L T8 or 4L T5HO N-L3393 $20 Fixture ≤250W LED, instead of 8L T8 or 6L T5HO N-L4347 $30 Fixture ≤300W LED, instead of 10L T8 or 8L T5HO N-L4795 $45 Fixture ≤350W LED, instead of 12L T8 or 10L T5HO N-L4796 $60 Fixture

LED TRACK/ACCENT FIXTURES Requirements: • Complete Table A of the "Lighting Incentive Catalog Supplemental Data Sheet" for these measures.

• Fixtures must be listed on ENERGY STAR and in a category not defined by linear ambient (page 11) or downlight (page 14) measures. Eligible fixtures may also be DLC SSL QPL listed (TRT V5.0 or higher) in the “Track or Mono-point Luminaires” or “Wall-wash Luminaires” primary use categories. Fixtures must be intended for commercial use. • Must be permanently wired fixtures and include housing, lens, heat sink, driver, and light source.

• For baseline fixture wattage, multiply installed fixture wattage by 2.5. NEW CONSTRUCTION AND MAJOR RENOVATIONS Measure Description LED track/mono/accent fixtures instead of incandescent, CFL, or HID fixture

Code

Incentive

Unit

N-L4813*

$0.10

Watt Reduced

* Supplemental Data Sheet needed

REMINDER New Construction fixture incentives are intended for projects with 400 or fewer installed fixtures. Projects with more than 400 fixtures must use the Lighting Power Density measure on page 19.