FURNACES Requirements: • Eligibility for furnace and single package vertical unit measures is based on customer having both an eligible electric and natural gas provider. • Furnaces and single package vertical unit must meet the minimum efficiency requirements listed and be a sealed combustion unit. Efficiency ratings will be verified using the AHRI database (ahridirectory.org). • Furnaces and single package vertical units must have a single speed, multi-speed, or variable speed electronically communicated motor (ECM). Permanent split
capacitor (PSC) motors are not eligible. Air handlers with an ECM are not eligible. • Provide a manufacturer’s specification sheet to document the required features. • Provide input capacity of furnace or single package vertical units (in MBh) in Section 7 on the Incentive Application. • Furnaces must have a multi-stage burner and have at least two firing stages. • Furnaces listed on the Focus on Energy residential furnace qualified products list does not guarantee the furnace has all features required for agribusiness incentives. EQUIPMENT UPGRADES AND RETROFITS Measure Description Code Incentive
Unit
Furnace with ECM, ≥95%+ AFUE, 2 stages of heat (Natural Gas or Propane)
H3491
$270
Furnace
Furnace with ECM, ≥90%+ AFUE, 2 stages of heat (Natural Gas or Propane)
H3492
$120
Furnace
NEW CONSTRUCTION AND MAJOR RENOVATIONS Measure Description
Code
Incentive
Unit
Furnace with ECM, ≥95%+ AFUE, 2 stages of heat (Natural Gas or Propane)
N-H3491
$220
Furnace
Furnace with ECM, ≥90%+ AFUE, 2 stages of heat (Natural Gas or Propane)
N-H3492
$100
Furnace
UNIT HEATERS Requirements: • Unit heater must be an upgrade from a standard efficiency (typically 80%-84% thermal efficiency) unit heater.
• Steam or hot water coils/systems are not eligible. Natural gas fired only. • Must be vented and condensate drained per manufacturer specifications. • Direct fired rooftop units/make-up air units are not eligible for this incentive. • Must replace an existing non-condensing unit heater or be installed instead of a non-condensing unit heater. • Provide a manufacturer’s specification sheet to document the features and efficiency level of the unit heater, including input capacity in MBh. EQUIPMENT UPGRADES AND RETROFITS Measure Description Code Incentive Unit Unit Heater, ≥90% Thermal Efficiency (Natural Gas or Propane) H5436 $2.50 MBh NEW CONSTRUCTION AND MAJOR RENOVATIONS Measure Description Code Incentive Unit Unit Heater, ≥90% Thermal Efficiency (Natural Gas or Propane) N-H5436 $1.25 MBh