VENTILATION/EXHAUST FAN — OTHER APPLICATION (NON-DAIRY) Requirements: • Product must meet the performance requirements below.
• 36 to 47 inch fans must be greater than or equal to 17.0 cfm/watt at 0.10 inches of static pressure. • ≥ 48 inch fans must be greater than or equal to 21.0 cfm/watt at 0.10 inches of static pressure. • Variable speed fans do not have a minimum performance requirement.
• Test report must be included with Fan Application for MMIDs AG5093 and AG5094 to verify performance. Acceptable test report sources include Bio- Environmental and Structural Systems (BESS) labs, an accredited Air Movement and Control Association (AMCA) testing facility or other third party lab in accordance with AMCA/ANSI 210 or 230 test procedures.
• Must operate a minimum of 4,000 hours annually to be eligible. • Variable speed must be automatically controlled by temperature. • Variable speed fans are not eligible for other variable frequency drive incentives. • Full fan model number and fan diameter must be included on invoice. EQUIPMENT UPGRADES AND RETROFITS Measure Description
Code
Incentive
Unit
Ventilation/Exhaust Fan, Other (non-dairy), 36-47” (17.0 cfm/watt)
AG5093
$75
Fan
Ventilation/Exhaust Fan, Other (non-dairy), ≥ 48” (21.0 cfm/watt)
AG5094
$100
Fan
Ventilation/Exhaust Fan, Other (non-dairy), ≥ 48” with Variable Speed
AG5095
$250
Fan
NEW CONSTRUCTION AND MAJOR RENOVATIONS Measure Description
Code
Incentive
Unit
Ventilation/Exhaust Fan, Other (non-dairy), 36-47” (17.0 cfm/watt)
N-AG5093
$75
Fan
Ventilation/Exhaust Fan, Other (non-dairy), ≥ 48” (21.0 cfm/watt)
N-AG5094
$100
Fan
Ventilation/Exhaust Fan, Other (non-dairy), ≥ 48” with Variable Speed
N-AG5095
$250
Fan
CIRCULATION FAN — DAIRY APPLICATION Requirements: • Product must meet the performance requirements below.
• 36 to 47 inch fans must be greater than or equal to 20.0 lbf/kW. • ≥ 48 inch fans must be greater than or equal to 24.5 lbf/kW.
• Test report must be included with Fan Application to verify performance. Acceptable test report sources include Bio-Environmental and Structural Systems (BESS) labs, an accredited Air Movement and Control Association (AMCA) testing facility or other third party lab in accordance with AMCA/ ANSI 210 or 230 test procedures. • Full fan model number and fan diameter must be included on invoice. EQUIPMENT UPGRADES AND RETROFITS Measure Description Code Incentive Unit Circulation Fan, Dairy, 36-47” (20.0 lbf/kW) AG5086 $40 Fan
Circulation Fan, Dairy, ≥ 48” (24.5 lbf/kW)
AG5087
$50
Fan
NEW CONSTRUCTION AND MAJOR RENOVATIONS Measure Description
Code
Incentive
Unit
Circulation Fan, Dairy, 36-47” (20.0 lbf/kW)
N-AG5086
$40
Fan
Circulation Fan, Dairy, ≥ 48” (24.5 lbf/kW)
N-AG5087
$50
Fan
28