B3 SPLIT SYSTEM AIR CONDITIONING — CONDENSING UNIT ONLY — INCENTIVE CODE: H3909
PAGE 24
(C) FULL LOAD EFF TO QUALIFY (EER) (FROM MEASURE DESCRIPTION PG 28)
(B) AHRI RATED FULL LOAD EFFICIENCY (EER, 2 DECIMALS)
(A) AHRI RATED CAPACITY (TONS, 2 DECIMALS)
(D) DELTA EFFICIENCY (B - C)
(E) ADDITIONAL INCENTIVE (D X $/TON)
(F) BASE INCENTIVE ($/TON)
(G) INCENTIVE RATE ($/TON) (E + F)
REQUESTED INCENTIVE* (A X G)
EQUIP #
(Example) AC 1
15.00
12.00
11.50
0.5
$2.50
$20.00
$22.50
$337.50
C CHILLERS (BUILDING COOLING LOAD) — INCENTIVE CODE: H4712, H4713, H4714, H4715
PAGE 25
BUILDING/SPACE DESIGN COOLING LOAD (TONS)
CHILLER LOCKOUT TEMPERATURE (°F)
CODE COMPLIANCE PATH: A OR B
EQUIP TYPE
BASE OR TRIM CHILLER?
(Example) Air-Cooled
90
Base
53 °F
Path A
D
CHILLERS (EQUIPMENT PERFORMANCE) —
PAGES 25–27
INCENTIVE CODE: H4712, H4713, H4714, H4715, H4716, H4717, H4718, H4719, H4720, H4721, H4722, H4723, H4724, H4725, H4726, H4727, H4728, H4729, H4730, H4731, H4732, H4733, H4734, H4735
(B) MAX FULL LOAD (KW/TON) (FROM MEASURE DESCRIPTION PG 21-23)
(D) MAX PART LOAD (IPLV) (KW/TON) (FROM MEASURE DESCRIPTION PG 30)
(C) AHRI RATED FULL LOAD EFFICIENCY (KW/TON, 3 DECIMALS)
(E) AHRI RATED PART LOAD EFFICIENCY (IPLV) (KW/TON, 3 DECIMALS)
(I) INCENTIVE RATE ($/TON) (G + H)
(A) AHRI RATED CAPACITY (TONS, 3 DECIMALS)
(F) DELTA
(G) ADDITIONAL INCENTIVE ($/TON)
(H) BASE INCENTIVE ($/TON)
REQUESTED INCENTIVE* (A X I)
EQUIP #
EFFICIENCY: ((B - C) + (D - E))
$8.00
$18.00
(Example) Chiller 1
95.000
1.160
1.120
0.880
0.840
0.080
$10.00
$1,710.00
E ENERGY RECOVERY VENTILATOR (ERV) — INCENTIVE CODE: H2314, H5082
PAGE 28
COOLING SYSTEM EFFICIENCY (KW/TON OR EER, 2 DECIMALS)
AHRI NET TOTAL SUMMER EFFECTIVENESS %
AHRI NET TOTAL WINTER EFFECTIVENESS %
HEATING SYSTEM EFFICIENCY (%)
HOURS OF OPERATION (HRS/WK)
SUPPLY AIRFLOW (AHRI LISTED CFM)
EQUIP #
(Example) ERV 1
60 hrs/wk
2,000
81%
77%
80%
1.20 kW/ton
F ADVANCED ROOFTOP UNIT CONTROLLERS — INCENTIVE CODE: H3964
PAGE 30
WEEKDAY OPEN / CLOSE TIMES
SATURDAY OPEN / CLOSE TIMES
SUNDAY OPEN / CLOSE TIMES
NOMINAL COOLING CAPACITY (TONS)
ECONOMIZER OPERATIONAL? (Y/N)
HEATER TYPE (NATURAL GAS OR ELECTRIC)
EQUIP #
FAN HP
(Example) RTU 1
15.00
Natural gas
5
Yes
7 AM / 9 PM
8 AM / 10 PM
11 AM / 7 PM
G DEMAND CONTROLLED VENTILATION (DCV) — INCENTIVE CODE: H2853 (DCV FOR MULTIPLE ZONE)
PAGE 31
(A) EXISTING MIN OUTSIDE AIR FLOW (CFM)
(B) NEW MIN OUTSIDE AIR FLOW (CFM)
OUTSIDE AIR FLOW REDUCED (CFM) (A-B)
SPACE HEATING EFF (%)
AREA SERVED TYPE
AHU COOLING SIZE (TONS)
HOURS OF OPERATION/ WEEK
SPACE COOLING (Y/N)
EQUIP #
(Example) DCV 1
Yes
83%
Office
12
60
5,000
3,000
2,000
9