COMPREHENSIVE LIGHTING SOLUTIONS
FIXTURE OR RETROFIT KIT UPGRADE WITH CONNECTED CONTROLS Requirements: • All projects must be pre-approved. Call 800.762.7077 or contact your Energy Advisor before you start your project. Pre-approval is considered complete once an incentive agreement is signed by the customer and returned to Focus on Energy. • Documentation required for pre-approval: • Proposal detailing existing and proposed fixture type(s), quantities, and model numbers with options. • Proposed control system specifications. • Existing and proposed footcandles (either measured or calculated) at working surface for space type representing the most square footage. • Completed CLS workbook. Download a copy at focusonenergy.com/catalogs. • New fixtures/retrofit kits must be ENERGY STAR certified or DLC SSL QPL listed (TRT V5.0 or higher). • For DLC listed equipment, use the DLC “Tested Electrical Performance” data for wattage of new equipment. If the DLC tested data is not available and only “Reported Electrical Performance” data is available, use the wattage listed on the specification sheet of the new equipment if the data is more current than the DLC listed family data. • Control systems must be DLC NLC QPL listed (NLC5 or higher) and have the following Networked Lighting Controls capabilities set up and operational for individual fixtures: • Occupancy sensing. • Zoning. • Individual addressability. • All installations are expected to meet current IESNA recommendations for delivered light level and uniformity. Compliance is the responsibility of the installer/designer. • Customers can apply for either a fixture or retrofit kit upgrade (see L5029 on page 40) or upgrade with connected controls (see table below). Specific fixtures may apply for only one option, but both measures can be used on a project if some fixtures have NLC controls and some do not. • Fixtures or retrofit kits with connected controls are eligible. Equipment is not eligible for additional fixture/retrofit kit incentives. • Systems are NOT eligible for additional control incentives (i.e., daylighting, high bay, or non-high bay controls). • Lamp-only upgrades, such as TLEDs, are NOT eligible for CLS incentives. • Interior lighting system must operate a minimum of 2,000 hours annually to be eligible.
EQUIPMENT UPGRADES AND RETROFITS Measure Description
Code
Incentive
Unit
CLS – Fixture or Retrofit Kit with Connected Controls, Interior
L5031
$0.45
Watt Reduced
CLS – Fixture or Retrofit Kit with Connected Controls, Exterior
L5030
$0.50
Watt Reduced
Incentive amount is limited to 50% of project cost, including equipment and external labor.
REMINDER Planning a new construction building or renovation project? Visit focusonenergy.com/business/whole-building for more information on incentives for these buildings.
46
Powered by FlippingBook