INTERIOR LIGHTING LINEAR LIGHTING FIXTURES
General Requirements: Incentives are available for replacing T8 or T12 fixtures with LEDs as described in the sections below. For fixtures with field adjustable lighting output, refer to Field Adjustable Lighting Output Guidance on page 11 for additional requirements. Manufacturer and model number(s) are required. Product categories listed below do not imply equivalency — all installations are expected to meet current Illuminating Engineering Society of North America (IESNA) recommendations for delivered light level and uniformity. Compliance is the responsibility of the installer. LED HIGH-PERFORMANCE TROFFER (1X4 AND 2X4) Requirements: • For 1-for-1 replacement of T12 or standard T8 fluorescent fixtures as noted in measure descriptions. • 1x4 LED products must be DLC SSL QPL listed (TRT V5.0 or higher) in either the “1X4 Luminaires for Ambient Lighting of Interior Commercial Spaces,” “Linear Retrofit Kits for 1X4 Luminaires,” or “Integrated Retrofit Kits for 1X4 Luminaires” primary use categories. • 2x4 LED products must be DSL SSL QPL listed (TRT V5.0 or higher) in either the “2X4 Luminaires for Ambient Lighting of Interior Commercial Spaces,” “Linear Retrofit Kits for 2X4 Luminaires,” or “Integrated Retrofit Kits for 2X4 Luminaires” primary use categories. • Other LED configurations may qualify for a custom incentive. • Incentives available for common areas only.
EQUIPMENT UPGRADES AND RETROFITS Measure Description
Code
Incentive
Unit
1X4 or 2X4 LED, ≤ 43W replacing 1- or 2-lamp T8 or T12 troffer
L5459
$5.00
Fixture
2X4 LED, ≤ 55W replacing 3- or 4-lamp T8 or T12 troffer
L3111
$20.00
Fixture
PRO TIP Have you considered Networked Lighting Controls? Take full advantage of your LED investment and harness benefits like remote diagnostics, energy monitoring, and bi-level control.
LED HIGH-PERFORMANCE TROFFER (2X2) Requirements: • Must be DLC SSL QPL listed (TRT V5.0 or higher) in either the “2X2 Luminaires for Ambient Lighting of Interior Commercial Spaces,” “Linear Retrofit Kits for 2X2 Luminaires,” or “Integrated Retrofit Kits for 2X2 Luminaires” primary use categories. • 2G11 base lamps replaced must have a nominal lamp wattage of 40–55 watts. • Other LED configurations may qualify for a custom incentive. • Incentive available for common areas only.
EQUIPMENT UPGRADES AND RETROFITS Measure Description
Code
Incentive
Unit
2X2 LED, ≤ 36W, replacing Fixture with 2 or more T8 or T12 Lamps
L3400
$8.00
Fixture
2X2 LED, ≤ 85W, replacing Fixture with 2 or more 2G11 Base Lamps
L3401
$18.00
Fixture
34