2024 Multifamily Catalog

VARIABLE FREQUENCY DRIVES (VFDS)

VARIABLE FREQUENCY DRIVES (VFD) Requirements: • Complete Table K of the “2024 HVAC and Plumbing Incentive Supplemental Data Sheet” for this measure. • For the “VFD Application” column, enter “Chilled Water Distribution Pump,” “HVAC Heating Pump,” “Pool Pump,” “Boiler Draft Fan,” “Cooling Tower Fan,” or “HVAC Fan.” • For the “Controls Before VFD” column, enter “Outlet Control Valve,” “Bypass Valve,” “Discharge Damper,” “Inlet Guide Vanes,” “On/Off,” “None,” or “Other” and then describe. • The individual motors controlled by the VFD must operate a minimum of 2,000 hours annually and may not exceed 500 horsepower. VFDs controlling motors larger than 500 HP or that run < 2,000 hours annually may be eligible for a custom incentive. • VFD speed must be automatically controlled by differential pressure, flow, temperature, or other variable signal. • VFDs added to chillers and kitchen ventilation hoods do not qualify for this incentive. Refer to “Cooling Systems” section of this catalog if installing a chiller with a VFD or apply for a custom incentive if installing a VFD somewhere else. • VFD must be installed on a centrifugal or axial flow pump or fan, i.e., a variable torque load. • Staged air volume systems (using a VFD to achieve two-speed fan control on a rooftop unit) are not eligible but may be eligible for a custom incentive. General Requirements: The system controlled must have significant load diversity that will result in savings through motor speed variation. Units installed only to allow soft starts are not eligible. Redundant or backup units do not qualify. Replacement of an existing variable frequency drive (VFD) does not qualify. VFDs may not be beneficial in pump systems where static head makes up a large portion of the total system head. It is also important that the load on the system vary over time to take advantage of the savings that a VFD can provide. Be sure to understand these aspects of your system and discuss them with the equipment vendor in advance of applying VFD technology.

EQUIPMENT UPGRADES AND RETROFITS Measure Description

Code

Incentive

Unit

Variable Torque VFD, Boiler Draft Fan

H2640*

$40.00

HP

Variable Torque VFD, Cooling Tower Fan

H2641*

$40.00

HP

Variable Torque VFD, HVAC Fan

H2643*

$40.00

HP

Variable Torque VFD, Chilled Water Distribution Pump

H2726*

$40.00

HP

Variable Torque VFD, HVAC Heating Pump

H2644*

$40.00

HP

Variable Torque VFD, Pool Pump Motor

H2646*

$40.00

HP

*Supplemental data sheet needed.

33

Powered by