DEMAND CONTROL VENTILATION (DCV) Requirements: • Complete Table H or I of the “2024 HVAC and Plumbing Incentive Supplemental Data Sheet” depending on the appropriate measure below. • For the “Area Served Type” column, enter a short descriptor of the space type, such as lobby, fitness center, etc. • For the “New Min Outside Air Flow” column, enter CFM of occupant portion of the minimum outside air reduced when not in economizer mode, not total CFM provided by the AHU or RTU. At a minimum, the occupant portion of the outside airflow should be set to the average number of occupants in the zones served by the AHU/RTU multiplied by 7.5 CFM per occupant (current code minimum). See Chapter SPS 364, Heating, Ventilating, and Air Conditioning at docs.legis.wisconsin.gov/code/admin_code/sps/safety_and_buildings_and_environment/361_366/364. • For the “Economizer” column, enter “DB” for dry bulb or “Enthalpy.” • For the “AHU Controls” column, enter “No Setback,” “EMS” for energy management system, or “T-Stat” for programmable thermostat. • For air handling unit (AHU) and rooftop units (RTU), DCV controls must measure CO 2 levels in the conditioned space and provide the “code” required “minimum” level of outside air (actual occupant portion) without over-ventilating. Sensors should be wall-mounted at an appropriate height within the space. Sensors may be installed in return air ductwork only if space mounting is not possible and the return duct serves a single zone. • Spaces controlled by DCV must be heated with natural gas or electricity from a participating utility, but are not required to be air conditioned. DCV installations required by code are not eligible. • DCV for AHU measure is intended for central air handling units that have multiple individually controlled spaces and will require a CO 2 sensor in each occupied zone served by the AHU. Unit ventilators may be eligible for the multiple zone incentive (H2853) as long as all other requirements are met, including a functioning economizer. • Single zone RTUs must apply using the DCV for Single Zone RTU measure (H3266) and are not eligible under the DCV for AHU measure (H2853). • All installations must comply with code requirements for ventilation. • DCV installations are expected to provide additional ventilation air when sensing high CO 2 levels during occupied modes of operation (including heating, cooling, and ventilation-only modes). • If system is custom-built using a CO 2 sensor and the buildings existing automation system, provide a copy of the control sequence that was programmed into the building automation system.
CO 2
EQUIPMENT UPGRADES AND RETROFITS Measure Description
Code
Incentive
Unit
DCV for Multiple Zone RTU/AHU/Unit Ventilator
H2853*
$0.20
CFM Reduced
DCV for Single Zone RTU/AHU
H3266*
$430.00
RTU/AHU
*Supplemental data sheet needed. Incentive amount is limited to 50% of the project cost, including equipment and external labor.
PRO TIP CO 2 sensors with a 2% accuracy rating are recommended for long-term reliability.
PRO TIP Spaces with large variations in occupancy are great candidates for DCV. Controls allow the HVAC system to determine the proper level of ventilation without creating unnecessary heating and cooling loads.
PARKING GARAGE VENTILATION CONTROLS Requirements: • Complete Table J of the “HVAC/Plumbing Incentive Catalog Supplemental Data Sheet” for this measure. • Garage Size (sq ft),” “Heating System Capacity,” “Heating System Efficiency,” and “Heating Set Point” are only required for heated garages. • Install carbon monoxide (CO) controls to control parking garage exhaust fans that meet all state and local codes. • Current system must run 24/7. • Heated garages must be heated by either natural gas furnaces, natural gas unit heaters, or hot water/steam foam on an on-site natural gas boiler. Garages heated by municipal steam systems (i.e., “city steam”) are not eligible.
EQUIPMENT UPGRADES AND RETROFITS Measure Description
Code
Incentive
Unit
Parking Garage Ventilation Controls
H4837*
$120.00
System
Parking Garage Ventilation Controls with Heating
H3493*
$250.00
System
*Supplemental data sheet needed.