2024 Multifamily Catalog

REMINDER Planning a new construction building or renovation project? Visit focusonenergy.com/business/whole-building for more information on incentives for these buildings.

SPLIT SYSTEM AIR CONDITIONING – CONDENSING UNIT ONLY Requirements: • Complete Table C of the “2024 HVAC and Plumbing Incentive Supplemental Data Sheet” for this measure.

• For the “Min. Eff. To Qualify” column, use the value listed in the Measure Description below (11.5 EER). • For the “Delta Efficiency” column, use “AHRI Rated Full Load Efficiency” – “Min. Eff. To Qualify.” • For the “Incentive Rate” column, use “Additional Incentive” + “Base Incentive.” • For the “Total Incentive” column, use “AHRI Rated Capacity” x “Incentive Rate.” • Only complete one line of supplemental data sheet if multiple of the exact same model number were installed.

• Incentive is for the installation of high-efficiency condensing units for use in split system air conditioning systems. The base incentive rate for meeting the minimum efficiency is $20.00/ton, with an additional $5.00/ton incentive for each 1.0 EER that the cooling system exceeds the minimum efficiency. For example, a 15.00 ton, 12.1 EER condensing unit would be eligible for a $20.00/ton + (0.6 EER over minimum x $5.00/ton) = $23.00/ton incentive. • Look for the Cooling Eligibility Screening Tool at focusonenergy.com/catalogs for assistance with determining equipment eligibility and incentive rate. • Rated AHRI efficiency must meet or exceed minimum ratings shown for EER. AHRI-verified cooling capacity and EER will be used to calculate the incentive. • Equipment ≥ 20.83 tons is not listed in the ahridirectory.org . For this equipment, provide manufacturer performance data sheet that indicates ratings are “at AHRI conditions.” • For multiple of the exact same model number, complete the Incentive Application as follows: enter qty @ tons each in the # of Units column (example: 3 @ 15.00). • Condensing units may be included in the Split and Packaged Systems Incentives (H4368, H4369, H4370, H4371) or the Condensing Unit Only Incentives (H3909), but not both. • Must be a central plant type arrangement that serves multiple dwelling units in the multifamily building.

EQUIPMENT UPGRADES AND RETROFITS Measure Description

Code

Incentive

Unit

$20.00/ton + $5.00/ton per 1.0 EER over min.

Split System A/C Condensing Unit Only, ≥ 11.25 tons, ≥ 11.5 EER

H3909*

Ton

*Supplemental data sheet needed.

PRO TIP Additional system strategies include variable speed fans and compressor controls to more effectively use the refrigerant and modulate the temperature and amount of cooled air supplied to the space. See demand controlled ventilation (DCV) and smart thermostats for additional savings opportunities.

24

Powered by